×
Free Shipping @ Any Price
Best Price GUARANTEE
30 days money back
Honeywell 293712 2 INCH DS06 "DIALSET" LOW LEAD PRESSURE REGULATING
click to zoom in
  • sku METO_AMZ-3044
  • upc 085267994286
  • Weight: 0.00 LBS

Honeywell 293712 2 INCH DS06 "DIALSET" LOW LEAD PRESSURE REGULATING

Price: 2099-12-31 $527.80
Free Shipping
In stock
1 days
  • Shopper Award

2 INCH DS06 "DIALSET" LOW LEAD PRESSURE REGULATING

The 2IN DS06 DialSet Low Lead Pressure Regulating Valve is a low lead, one port high density reducing valve that maintains pressures within the 0-75 psi range at the end of the installing tubing. The 2IN DS06 DialSet works on a set pressure, therefore upon initial use of water; it may appear to operate too slowly until the system reaches its desired operating pressure. For best results, this valve should be installed when there is at least 30 ft of line pressure prior to the valve.

The 2 in. Dial-Set Low Lead Pressure Regulating Valve, CSA Certified, models DS06 and DS06SL is designed to safely control pressure at the tank inlet of a water heater or boiler during a system pressure drop. During low water flow conditions, the dial can be advanced clockwise to achieve an increased flow and, thereby, increased water temperature.

The DS-06-1 and DS-06 DialSet low lead, pressure regulating controls are direct acting, solenoid-operated, pressure-reducing control valves designed to reduce pressures up to the maximum working pressure of the equipment being protected. The valve is intended for use in applications where a firm, constant low downstream pressure is needed.

The DIALSET Low Lead Pressure Regulating Valve is a monitered, on/off style bypass device which straddles the water heater and building drain system. It may be installed in place of a primary pressure relief valve whenever water heater discharge flows are sufficient to assist in heat exchanger cleaning cycles. It may also be installed as a stand-alone device in systems not having a primary low lead relief? valve. For stand-alone application, use with a presetting temperature relief valve or installation of a remote control temperature power limiting valve to control heat exchanger cleaning cycles.

Achieve and maintain the proper low-lead pressure with the Honeywell Dialset 2 in. Pressure-Regulating Valve. This is a low-lead version of the Regulator that comes standard with our plastic pipe system, making it both affordable and efficient.

The HS293712 dial set pressure reducing 1/2 inch npt brass regulator offers precise control using the relatively high pressure range of 30 to 100 psi without a gauging station.

The DS series has rubber bonnets for low lead applications and adjustable pressure settings.

1 days
  • upc 085267994286
  • Weight: 0.00 LBS
  • Date First Available :December 11, 2014
  • Item Weight:11.1 Pounds
  • Manufacturer:Honeywell, Inc.
to top