ASCO 68646 Aluminum Body Low Pressure Direct Acting Fuel Gas Shutoff Valve, 1" Pipe Size, 2-Way Normally Closed, Nitrile Butylene Sealing, 1" Orifice, 14 Cv Flow, 120V/60 Hz, 110V/50 Hz.
click to zoom in
  • Brand: ASCO

  • sku METO_AMZ-3449
  • upc
  • Weight: 0.00 LBS

ASCO 68646 Aluminum Body Low Pressure Direct Acting Fuel Gas Shutoff Valve, 1" Pipe Size, 2-Way Normally Closed, Nitrile Butylene Sealing, 1" Orifice, 14 Cv Flow, 120V/60 Hz, 110V/50 Hz.

Price: 2099-12-31 $207.93
Free Shipping
In stock
1 days
  • Shopper Award

120V 1" 2-WAY N.C. SAFETY SHUTOFF G

The ASCO 68646 Aluminum Body Low Pressure Direct Acting Fuel Gas Shutoff Valve 1" Pipe Size, 120V 1'' 2-WAY N.C. SAFETY SHUTOFF Gate Valve features [a variety of benefits].

If you are looking for commercial safety gas valves, then look no further than the ASCO 68646 1" 2-Way Low Pressure Direct Acting Fuel Gas Shutoff Valve. This valve works effectively on residential units as well. The commercial safety gas valve is featured in other sizes and orifices.

The ASCO 68646 gas shutoff valve is designed to use with natural gas to stop the flow of fuel. Part Number 68646 is made with an aluminum body and comes in a tan gray color. It has a 1" pipe size, 2-Way Normally Closed, Nitrile Butylene Sealing, 1" orifice, 14 CV flow, 120V/60 Hz, 110V/50 Hz and is self-closing.

Safe operation of the heating system is paramount in commercial building, laboratories and other applications. Low pressure gas shutoff valves help to ensure a safe installation. These direct acting shutoff valves feature two-way normally closed valve action, aluminum body, 1" pipe size, 14 CD flow rating and a 1-1/2"L x 1-1/2"W x 1/4"H overall size. This means that the ASTM B602 & UPC D10790 compliant shutoff valve will allow free flow with 50 psig gage up to 10' away from shutoff.

Designed for the safe shutoff of fuel gas to the burner in a radiant heating system. It is used for 1" pipe systems with 2-way normally closed valves. The valve has built-in heat and pressure relieving which eliminates the need for an external pressure regulator.

This Safety Shutoff should only be installed where a high level of personal safety is provided by trained personnel. Auxiliary controls and protective devices must be installed in accordance with all local codes and ordinances. Use this Safety Shutoff with No. 6 or No. 8 Crosses and 1" Pipe Size (Fh). This valve shall not be used in the direct outpouring of natural gas into fireboxes. When this valve is used in conjunction with a Style X shutoff valve, it shall always be placed on the discharge side of the Style X shutoff valve. Never place a Safety Shutoff directly on any line carrying oil

This Direct Acting Gas Shutoff Valve senses pressure drops caused by an interruption in the flow of gas. The chamber is designed to close upon loss of pressure and remain closed until sufficient pressure has been restored to seat the valve. This is a safety device that should be installed at all propane tank installations. Aluminum body, zinc or brass plated 1" pipe size, rated 14CV Open flow