DUAL PRESSURE SWITCH REPLACES SWT02357
TRANE 332373 Dual Pressure Switch. The TRANE 332373 replacement dual pressure switch is for use with TRANE heat pumps that require SWT02357. This DUAL PRESSURE SWITCH REPLACES SWT02357 is also known as part number 332373.
This item is a direct replacement for the following existing model numbers - SWT02357. Reverse polarity protection ensures that if power is applied to this product backwards, no damage will occur. This DUAL PRESSURE SWITCH operates at 0-150 psi and 0-0 psi with 1/2 to 2 HP motors. With an operating temperature of 40 degrees F to 140 degrees F, the SWT02357 is suitable for many various industries, including food service, hospitals, motels, schools and more.
This is a new aftermarket dual pressure switch. This new pressure switch fits the following models of Trane Air Conditioners: Heating Models: TSCB20JA1003, TSCB2-13A13, TSCCB26JA1003, TSCCB2-13A13. Cooling Models: TB03050C181-2, TB03050C201-2, TB03050C241-2, TB03050C261-2. REPLACES SWT02357.
The 332373 Dual Pressure Switch is a sealed heavy duty unit designed for use with the following B/W pressure switch models: 3222HPR300, 3222HPR300A, 3224HPR313, 3224HPR313A, 3225HPR300, and 3225HPR300A. Also replaces switch numbers: SWT02357, SW495126317."
AmeriQual's Trane 332373 Dual Pressure Switch replaces the Sw-T02357 pressure switch. This is a genuine replacement part manufactured by Trane.
Some Trane room air conditioner/heat pump models used dual pressure switches, switch part numbers SWT02357, or equivalent. The models that had these switches are the 3TXT4048AAB, 6HNE8330AA04, 6HNE8330AB04, 6HNE8330AC04, 6HNE8330AD04, 6HNE8350AA04, 6HFX8350BA05, 9TNH8300CB07, 9TNH8300CC07
The Dual Pressure Switch is used to provide pressure switch redundancy in 2 to 3 ton packaged rooftop air conditioning equipment. The switch monitors low side pressure and operates the compressor contactor when low side pressure drops below the low setting.
Pressure switches and controls can help identify and control compressor and refrigeration system failures in HVAC systems. The 332373 pressure switch is a direct replacement for the following dual-pressure switches: 201643 201653 201654 202449 202454 202940 302076 TROUBLESHOOTING Use these diagrams to help determine what part failed in your cooling system. If you have just installed a new high-pressure cutout, there are no steps necessary to adjust the low-pressure cutout or set point. This may lengthen the time needed for the new high-pressure cutout to begin switching
This product is a Dual Pressure Switch which is designed to operate two zones of Trane air conditioning, heating or central air conditioning systems.
Our dual pressure switch works with our R410A condensing units. This two stage compressor switch monitors the suction side pressure by sensing the suction pressure. The switch allows the compressor to reach its cut-in pressure and then it changes to the second stage.
This dual pressure switch is suitable for use with systems containing boilers with electronic expansion valves. The pressure switch consists of a primary part and a secondary part which are connected. The internal switches are sealed to prevent product damage due to water entering the system. The internal holding force specification is not affected by the presence of solvents, but is dependent on the mounting method of the switch.
Now you can double the protection on your HVAC air handler system. The all-new double pressure switch monitors not only your heater but also your cooling system. It will shut off both systems if pressure is lost, giving you added protection for just one thin dime. Replace that old double pressure switch with the new Trane Double Pressure Switch, part #332373.